EEA: Electrical Energetics Grid Impedances, Short Circuit Currents, Automatic Trip-Out Ability and Ground Integrity (ADK: D-5/909)

The acquired knowledge is focused on assuring of safety conditions and protection against electrical shock by evaluating of automatic tripout ability and tripout time. Additional factors are used in calculations to protect transformers and built-in equipment in case of overheating. Several procedures and measuring methods are explained for maintenance in safe manner when work energized. The candidate will gain knowledge of evaluated parameters, the suggested limits from the standard and the examples of PASS / FAIL results. The responsibility of the candidate is the correct reports and markings and the appropriate acting and informing.

Areas of Application

  • Short-circuit currents in three-phase a.c. systems:
    • contribution of power station units,
    • contribution of windpower station units,
    • industrial transformers and belonging installations.
  • Automatic trip-out ability, earth bonding, dR Hi-Current testing.
  • Available short-circuit current at the test point, fuse characteristic evaluation, hot factor calculation and Isc minimum, background for arc flash and shock hazard present warnings and protection, incident energy & working distances, approach boundaries.
  • Short-circuit currents maximum and calculation of contact & touch voltages in case of fault.
  • Protection against electrical shock.
  • Low-voltage switchgear and controlgear – circuit-breakers in case of leakages, neutral currents or asymmetry.

Regulation, Literature and Standards

  • IEC / EN 60909 Short-circuit currents in three-phase a.c. systems
  • IEC / EN 60947-2 Low-voltage switchgear and controlgear – Part 2: Circuit-breakers
  • Manual for test equipment MI 3144 EURO Z & Application notes, Academy@Metrel

Upcoming Events

No event found!

Select your package & register for the exam

Shop for recommended presentations, guides, cheat sheets and charts. Get ready for examination and certification process.

Webinar EEA: 1 hour with QA

122,00 EUR

Presentations and guides

15,75 EUR

Online exam and certificate

96,00 EUR

Get your competency certified

Special offers

EEA 3in1 – 10% OFF

EEA: webinar, literature, online exam and certificate

233,75 EUR 210,38 EUR

VIP access

All available webinars

488,00 EUR

Online seminar

Tailored online seminar with live QA support

ADD TO CART
Half-day: 488,00 EUR
Full-day: 854,00 EUR

Webinars

Watch the educational webinars online. Check what is suitable for you in description before add to cart. Check special offer, buy and unlock the content.

Webinar I – Main Course

Webinar with QA support from specialist. Get certified!

Buy 3in1 token and get your personal access.

By buying 3in1 token you will get your personal access to webinar and to a specialist who will answer any question you may have.

Combine competences using our QUESTIONNAIRE.

Webinar EEA: 1 hour / QA support / 3 courses

Electrical Energetics Grid Impedances, Ipsc Trip-Out Ability and Ground Integrity - Metrel MI 3155 Eurotest XD and MI 3144 Euro Z

Basics with measuring methods to refresh the theoretical and practical knowledge.

Refresh your knowledge and prepare yourself for CPD competence certification.

Several procedures and measuring methods are explained for maintenance in safe manner when work energized.

by Metrel Academy

FREE Webinars

Watch the educational webinars online. Check special offer, buy and unlock the content.

by Metrel Academy
by Metrel Academy

Training Schedule

Safety First

Health & Safety at Work with Electricity

  • Use of personal protection equipment
  • Use of electrical equipment and barriers
  • Accessible life parts and limits of approach

Employer / Employee Responsibilities

  • Lockout / Tagout
  • Five safety steps
  • Work permit when energized

Job Briefing and Planning

  • Identify hazards
  • Ask
  • Check
  • Know
  • Think
  • Likelihood of occurrence
  • Prepare for emergency

Practical Knowledge with Measuring Methods and Procedures

 Inspections, Tests & Measurements

  • Visual inspection
  • Automatic tripout ability
  • Continuity and equalization testing
  • dR High-Current earth bonding testing
  • Ground integrity with High-Current method
  • Partial grounding by additional flex clamp method
  • Partial impedances of joints on live lines
  • Short-circuit current avilable
  • Short-circuit current minimum and hot factor evaluated
  • Short-circuit current maximum
  • Fault / contact / touch voltage evaluated
  • Z / Isc / Fuse protection evaluation
  • ELR relay tripout testing
  • Insulation resistance measurement
  • Functional checking
  • Power quality evaluation

Evaluation of Results

  • Find the PASS / FAIL / LIMIT values
  • Compare results to the limit
  • Bring the decision

Act and Inform Appropriately

  • Report the results
  • Mark the equipment accordingly
  • Enabling of further use when PASS
  • Rejecting the usage when FAIL
  • Inform and transfer the responsibility

Troubleshooting and Maintenance

  • Evaluate results, predict maintenance
  • Find faults and potential dangerous

Certification of Professional Qualification

Based on the knowledge gained in this training you will be ready for the certification of a professional qualification. After passing the exam you can obtain a certificate of competence for electrical safety of EEA Electrical Energetic Installations Automatic Trip-Out Ability.

The certification process – registration, examination, certification, registering and maintaining the register, notifications – are available through our testing centres worldwide, that will help and guide you through the process. Our trainers and specialists will support you with theoretical and practical experiences.

Get knowledge! Get certificate!

Educate yourself with instructional videos for FREE!

Substation Safety Inspection

Railway Ground Integrity

High versus Low Test Current

Grid Impedances Testing Set

Partial Grid Impedances

Partial Grid Impedances